185 changes: 170 additions & 15 deletions packages/modules/devices/tesla/tesla/counter.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,7 @@
#!/usr/bin/env python3
import logging
import math
import time
from requests import HTTPError

from modules.common.abstract_device import AbstractCounter
Expand All @@ -17,34 +19,187 @@
def __init__(self, component_config: TeslaCounterSetup) -> None:
self.component_config = component_config

# Throttle diagnostic logging (to avoid log spam in a 10s polling cycle)
self._last_energy_debug_log_ts: float = 0.0

def initialize(self) -> None:
self.store = get_counter_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))

@staticmethod
def _safe_float(val, default: float = 0.0) -> float:

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Default Werte werden zentral im CounterState gesetzt, damit sie konsistent sind.

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Bitte die Methode entfernen. Wenn Werte in einem Zyklus fehlen, wird eine Exception geworfen.
Es wird inkonsistent und der Code in jedem Modul sehr umfangreich, wenn überall default-Werte gesetzt werden.

try:
if val is None:
return default
return float(val)
except (TypeError, ValueError):
return default

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Die Methode und die Aufrufe kann entfallen, das ist zentral umgesetzt.

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Danke, ich entferne _safe_float() und verlasse mich auf die zentrale Behandlung. Mein ursprünglicher Gedanke war, unvollständige Tesla-Antworten robuster abzufangen.


@staticmethod
def _nearly_zero(x: float, eps: float = 1e-9) -> bool:
return abs(x) < eps

def _calc_currents_and_pf_from_pqu(

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Diese Berechnung erfolgt zentral im CounterState, wenn keine Ströme gesetzt sind, aber Phasenspannungen und Phasenleistungen vorhanden sind. Die Berechnung soll nicht in jedem Modul erfolgen.

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Im CounterState sind jedoch nur die Wirkleistungen vorhanden. Reale Ströme können dann nicht berechnet werden. Das sollte in einem anderen PR grundlegend überarbeitet werden.

Copy link
Copy Markdown
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Danke für den Hinweis.

Dann würde ich für diesen PR die lokale Stromberechnung im Tesla-Counter beibehalten. In meinem Setup liefert Tesla/Neurio für die Phase currents nur 0-Werte, und ohne diese Ableitung funktioniert das Lastmanagement nicht zuverlässig.

Den generischen Ansatz zur Berechnung realer currents im CounterState würde ich nicht in diesem PR lösen. Das wäre aus meiner Sicht ein separates Thema, wie von dir vorgeschlagen.

Ich reduziere den PR daher weiter auf:

reduzierte /api/status-Nutzung
schlankes fail-fast
Tesla-spezifische Stromableitung nur dort, wo die API keine brauchbaren currents liefert

Ist das in eurem Interesse?

Copy link
Copy Markdown
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Ich habe das bei mir umgesetzt und teste die Änderungen über Ostern. Anschließend würde ich den PR aktualisieren...

self, voltages: list[float], p_list: list[float], q_list: list[float]
) -> tuple[list[float], list[float]]:
"""
Calculates signed currents (A) and signed power factors per phase from P/Q/U.
Convention:
- sign of current follows sign of active power P (import +, export -)
- PF = P / S (signed)
- S = sqrt(P^2 + Q^2)
- I = S / U (signed via P)
"""
currents: list[float] = [0.0, 0.0, 0.0]
pfs: list[float] = [0.0, 0.0, 0.0]

for i in range(3):
u = self._safe_float(voltages[i], 0.0)
p = self._safe_float(p_list[i], 0.0)
q = self._safe_float(q_list[i], 0.0)

if self._nearly_zero(u):
currents[i] = 0.0
pfs[i] = 0.0
continue

s = math.sqrt(p * p + q * q) # apparent power [VA]

if self._nearly_zero(s):
currents[i] = 0.0
pfs[i] = 0.0
continue

# signed PF: magnitude P/S, sign from P
pf = p / s
pfs[i] = pf

# signed current: magnitude S/U, sign from P
i_mag = s / u
currents[i] = i_mag if p >= 0 else -i_mag

return currents, pfs

def update(self, client: PowerwallHttpClient, aggregate):
# read firmware version
status = client.get_json("/api/status")
log.debug('Firmware: ' + status["version"])
# read firmware version only at startup or after cookie renewal
if getattr(client, "cookie_renewed", False) or not getattr(self.store, "firmware", None):
try:
status = client.get_json("/api/status", fail_fast=False)
if isinstance(status, dict):
self.store.firmware = status.get("version", "")
log.debug("Firmware: %s", self.store.firmware)
except Exception:
# Non-critical: ignore status retrieval errors
pass
try:
# read additional info if firmware supports
meters_site = client.get_json("/api/meters/site")
cached = meters_site[0]["Cached_readings"]

# --- voltages / powers / reactive powers (per phase) ---
voltages = [self._safe_float(cached.get(f"v_l{phase}n")) for phase in range(1, 4)]
p_list = [self._safe_float(cached.get(f"real_power_{ph}")) for ph in ["a", "b", "c"]]
q_list = [self._safe_float(cached.get(f"reactive_power_{ph}")) for ph in ["a", "b", "c"]]

# --- currents from API (often all 0 on Neurio/Tesla) ---
api_currents = [self._safe_float(cached.get(f"i_{ph}_current")) for ph in ["a", "b", "c"]]

# --- energy counters ---
# IMPORTANT:
# We use ONLY aggregate["site"]["energy_imported"/"energy_exported"] as the source for
# imported/exported counters (same behaviour as the old/original module).
#
# We still *read* the per-phase energy fields (if available) ONLY for throttled diagnostic logging,
# to see whether per-phase sums diverge from aggregate counters.
def has_phase_energy(prefix: str) -> bool:
return all((prefix + s) in cached for s in ["_a", "_b", "_c"])

def sum_phase_energy_wh(prefix: str) -> float:
# Keep as Wh (openWB uses Wh in many places; your logs match that)
return (
self._safe_float(cached.get(prefix + "_a"))
+ self._safe_float(cached.get(prefix + "_b"))
+ self._safe_float(cached.get(prefix + "_c"))
)

imported = self._safe_float(aggregate["site"]["energy_imported"])
exported = self._safe_float(aggregate["site"]["energy_exported"])

# --- throttled diagnostics (1x per hour) ---
# Log aggregate vs. per-phase sums to spot counter mismatches without affecting behaviour.
now = time.time()
Comment thread
NicoP-codeing marked this conversation as resolved.
Outdated
if (now - self._last_energy_debug_log_ts) >= 3600:
self._last_energy_debug_log_ts = now

phase_imported = None
phase_exported = None
if has_phase_energy("energy_imported"):
phase_imported = sum_phase_energy_wh("energy_imported")
if has_phase_energy("energy_exported"):
phase_exported = sum_phase_energy_wh("energy_exported")

# These totals are present in Cached_readings too, but in some firmwares they can be absurd.
cached_total_imported = cached.get("energy_imported")
cached_total_exported = cached.get("energy_exported")

# Deltas only make sense if units match; still useful to see large divergences.
delta_imported = (phase_imported - imported) if phase_imported is not None else None
delta_exported = (phase_exported - exported) if phase_exported is not None else None

log.info(
"Powerwall energy debug (1h): aggregate_imported=%s aggregate_exported=%s "
"phase_sum_imported=%s phase_sum_exported=%s delta_imported=%s delta_exported=%s "
"cached_total_imported=%s cached_total_exported=%s",
imported,
exported,
phase_imported,
phase_exported,
delta_imported,
delta_exported,
cached_total_imported,
cached_total_exported,
)

# --- calculate PF + fallback currents if missing ---
calculated_currents, power_factors = self._calc_currents_and_pf_from_pqu(
voltages=voltages, p_list=p_list, q_list=q_list
)

# If all API currents are 0 -> use calculated currents
if all(self._nearly_zero(i) for i in api_currents):
currents = calculated_currents
log.debug(
"Tesla/Neurio phase currents missing (all 0). Calculated currents from P/Q and U."
)
else:
currents = api_currents
# PF still useful even if currents exist
log.debug("Using phase currents from Tesla/Neurio API.")

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Wenn es Modelle gibt, die keine Ströme liefern, dann dürfen diese im CounterState nicht gesetzt werden. Dann werden sie automatisch gesetzt.


powerwall_state = CounterState(
imported=aggregate["site"]["energy_imported"],
exported=aggregate["site"]["energy_exported"],
power=aggregate["site"]["instant_power"],
voltages=[meters_site[0]["Cached_readings"]["v_l" + str(phase) + "n"] for phase in range(1, 4)],
currents=[meters_site[0]["Cached_readings"]["i_" + phase + "_current"] for phase in ["a", "b", "c"]],
powers=[meters_site[0]["Cached_readings"]["real_power_" + phase] for phase in ["a", "b", "c"]]
imported=imported,
exported=exported,
power=self._safe_float(aggregate["site"]["instant_power"]),
voltages=voltages,
currents=currents,
powers=p_list,
power_factors=power_factors,
frequency=int(round(self._safe_float(aggregate["site"].get("frequency", 50)))),
serial_number=str(cached.get("serial_number", "")) if cached.get("serial_number") else "",
)
except (KeyError, HTTPError):

except (KeyError, HTTPError, IndexError, TypeError) as e:
log.debug(
"Firmware seems not to provide detailed phase measurements. Fallback to total power only.")
"Firmware seems not to provide detailed phase measurements. Fallback to total power only. (%s)",
str(e),
)
powerwall_state = CounterState(
imported=aggregate["site"]["energy_imported"],
exported=aggregate["site"]["energy_exported"],
power=aggregate["site"]["instant_power"]
imported=self._safe_float(aggregate["site"]["energy_imported"]),
exported=self._safe_float(aggregate["site"]["energy_exported"]),
power=self._safe_float(aggregate["site"]["instant_power"]),
)

self.store.set(powerwall_state)


component_descriptor = ComponentDescriptor(configuration_factory=TeslaCounterSetup)

Check warning on line 205 in packages/modules/devices/tesla/tesla/counter.py

View workflow job for this annotation

GitHub Actions / build

blank line at end of file
Loading
Loading