NT36532 touch protocol and sheng sensor configuration.
The tracker confirms tip-down on the second scan and reports the first position, including at the bottom edge. A new contact requires at least two sensor nodes above the noise floor. The panel reference updates after eight complete scans without a finger or palm. During a pinch with distinct peaks, each established contact keeps its ID. A partial dropout can retain the last position for up to three scans.
The device repository selects this component with its board inputs. Build requirements and scope are documented in the UniXNU site and component catalog.