Skip to content

Latest commit

 

History

History
37 lines (32 loc) · 4.78 KB

references.md

File metadata and controls

37 lines (32 loc) · 4.78 KB

Papers and practical questions

These linked papers explain the method and its limits. Publisher/DOI links and available author manuscripts are provided rather than redistributing journal PDFs.

Question Read What it contributes
Where do up-down estimation and pattern coefficients come from? Dixon WJ (1980), Efficient Analysis of Experimental Observations. Annual Review of Pharmacology and Toxicology 20:441–462. DOI Statistical background for the tabulated k approach.
Was this method established in rats? Chaplan SR et al. (1994), Quantitative assessment of tactile allodynia in the rat paw. Journal of Neuroscience Methods 53:55–63. DOI, PubMed Original rat validation using approximately 0.41–15.1 g.
Why do force labels, handle codes, and spacing matter? Bradman MJ et al. (2015), Practical mechanical threshold estimation in rodents using von Frey hairs/Semmes–Weinstein monofilaments: Towards a rational method. Journal of Neuroscience Methods 255:92–103. DOI, author manuscript Calibration and methodological limitations.
Why calculate logs from force? Is averaging spacing exact? Christensen SL et al. (2020), Von Frey testing revisited: Provision of an online algorithm for improved accuracy of 50% thresholds. European Journal of Pain 24:783–790. DOI, author manuscript Explains handle/target discrepancies and constant, flexible, and exact interval approaches. The exact method is not implemented here.
What related software exists? Gonzalez-Cano R et al. (2018), Up–Down Reader: An Open Source Program for Efficiently Processing 50% von Frey Thresholds. Frontiers in Pharmacology 9:433. Open-access paper A separate published tool for processing response patterns; not a validation of this repository.
Which rat handles and nominal labels are commonly used? NIH/NINDS, Rat hind paw mechanical allodynia protocol; Marvizon JC et al. (2015), Latent sensitization: a model for stress-sensitive chronic pain. Current Protocols in Neuroscience 71:9.50.1–14. DOI, full text NIH specifies the eight handles; Marvizon et al. also list nominal gram labels and protocol-specific boundary assignments.
Are floor assignments universal? Ding X et al. (2018), BDNF contributes to the neonatal incision-induced facilitation of spinal long-term potentiation and the exacerbation of incisional pain in adult rats. Neuropharmacology 137:114–132. DOI, institution-hosted paper Methods section 2.4.1 uses a 0.25 g floor and 15 g ceiling; another protocol above describes a different floor. Follow the chosen protocol explicitly.

FAQ

  • Is handle 4.08 filament number 4? No. It identifies the nominal 1 g filament. In the rat subset it is ID 3; rat ID 4 is the 2 g filament.
  • Does calculating Log_new prove the force is correct? No. It transforms the supplied force. Actual calibration requires physical measurement.
  • Does the mouse workbook apply to rats? Its mouse calibration does not. The response-pattern coefficients are species-independent and are separately distributed in data/dixon_k.csv for rat/custom calculations.
  • Does a k table contain every possible response string? No. This repository supports 248 tabulated patterns of lengths 2–9; other patterns need review.
  • Does a passing spacing check validate the entire experiment? No. The experiment must still follow its acquisition and stopping protocol.
  • Does selecting endpoint substitution solve censoring statistically? No. It is an explicit numerical convention. See boundary handling.
  • What should Methods report? Species, tested/calibrated forces and ID map, start/stopping rules, response coding, log convention, k-table source, delta method/value, boundary policy and counts, exclusions, statistical method, and software version/commit. Preserve the exported ladder with the data.

Sources checked 2026-10-05. The papers support particular methodological choices; their inclusion does not imply independent validation of all software outputs.