Skip to content

Commit 33cd1a2

Browse files
authored
Merge pull request #156 from mbel-tech/fatina-del-codice/sp5-design
Design SP5: water column, geometry, and vertical axis handling
2 parents f7f46ef + 678e44a commit 33cd1a2

1 file changed

Lines changed: 109 additions & 0 deletions

File tree

Lines changed: 109 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,109 @@
1+
# SP5 — water-column semantics and geometry the model cannot express
2+
3+
Design note for findings 5, 7 and the smaller items of finding 9 of the 3-D data-path review.
4+
Status: **draft for review**; nothing here is implemented. Decided with the requester: the water column
5+
bounds z for every 3-D metric (section 1); the mirrored horizontal plane is fixed (section 5); sessions on
6+
different vertical axes are refused at import (section 4). Based on `main` after #147, #150, #152
7+
and #155 (SP1-SP4).
8+
9+
## 1. The water column also bounds z for IL-16, IL-17 and GL-16 (finding 5)
10+
11+
**Today.** `apply_water_column` writes `depth` and the outside mask, which only IL-15 reads. IL-16 and
12+
GL-16 take `psess.z` through `geometry3d.positions_cm`; IL-17 takes `psess.z` through its own copy of
13+
that rule (`individual.py` ~2013). A user who enters a water column to exclude out-of-tank artefacts
14+
(reflections, a mis-triangulated keypoint) gets them out of IL-15 and still in the path length and
15+
speed. Fused sessions already behave the other way: their Z is `depth * height`, which is NaN outside
16+
the column.
17+
18+
**Decision (already made):** the column bounds z for every 3-D metric.
19+
20+
**Design.**
21+
- One helper `geometry3d.vertical_cm(psess)` returns the vertical coordinate in cm: `psess.z` with the
22+
samples in `depth_outside_mask` set to NaN (native), or `depth * depth_height_cm` (fused). Both
23+
`positions_cm` and IL-17 call it, so the two rules cannot drift apart again.
24+
- A sample outside the column is NaN, so a step touching it is dropped (the existing "a step needs all
25+
three coordinates" rule); nothing is clipped.
26+
- With no water column the behaviour is unchanged (z is used as is).
27+
- The exported `z_cm` column (SP2) stays the unmasked file coordinate: it is the data, not a metric
28+
input. The README states which samples the 3-D metrics dropped (`depth_outside` is already counted).
29+
- The Calibration page text for the water column says it also excludes samples from path length and
30+
speed.
31+
32+
**Tests that change on purpose.** `test_il15_with_the_water_column_counts_the_outside_values` asserts
33+
that the outside frames keep their 3-D path and speed (D-043's "z is absolute" reading). It becomes: IL-16
34+
and IL-17 are computed without the two outside frames, and equal the no-column values when nothing is
35+
outside. CHANGELOG notes the changed numbers for native projects that set a water column.
36+
37+
## 2. An inverted side view (finding 7)
38+
39+
**Today.** `FusionSettings` requires `surface_row < floor_row`. The depth formula
40+
`(y - surface_row) / (floor_row - surface_row)` is already correct for either order; the validator is
41+
the only thing refusing it, while the native `WaterColumn` accepts either order.
42+
43+
**Design.**
44+
- Replace the validator with "floor_row must differ from surface_row". Keep `surface_row >= 0`.
45+
- `fusion/align.py:108` computes the side's horizontal scale as `(floor_row - surface_row) /
46+
tank_height_cm`; with an inverted view that is negative and silently flips the agreement check's
47+
sign. Use the absolute value (the horizontal direction is already governed by `flip`).
48+
- The Fusion dialog's summary line and README keep printing the two rows as entered.
49+
- Tests: an inverted pair gives the mirror-image depth (`1 - d`) of the upright pair with the rows
50+
swapped, and the agreement RMS is unchanged.
51+
52+
## 3. Fusion dialog helper text (finding 7)
53+
54+
`horizontal_axis` and `flip` change only the view-agreement check and `suggest_offset`, never the
55+
fused positions, but the dialog lays them out beside the surface and floor rows. Add one line of helper
56+
text under them: "Used to check that the two views agree; does not change the fused positions."
57+
(`ui/dialogs/fusion_dialog.py`.) The guide screenshots for that dialog are regenerated.
58+
59+
## 4. Native sessions that disagree on the vertical axis (finding 7)
60+
61+
**Today.** `CalibrationConfig.water_column` is one `(surface_z, floor_z)` pair for the project, entered
62+
"on the file's own vertical axis" with a per-session `flip` compensation, but `vertical_axis` is only
63+
recorded in provenance. Two native files read with different `vertical_axis` (or calibrated in separate
64+
sessions with unrelated origins) share a column that means different things for each.
65+
66+
**Design.**
67+
- `_native_rule` (the import rule that already refuses mixing and unit mismatches) also compares
68+
`vertical_axis`: a batch or project whose native sessions use different vertical axes is refused with
69+
a message naming them, like the unit rule. `flip` may differ (it is already compensated).
70+
- Different origins cannot be detected from the files. The Calibration page says, next to the water
71+
column fields, that one surface and floor apply to every session, so they must share an origin.
72+
- Test: adding a second file with another `vertical_axis` is refused before it is listed.
73+
74+
## 5. Smaller items from finding 9
75+
76+
- **`VideoInfo.n_frames` for a gappy file** (`readers/assemble.py:291`) is the row count. A file with
77+
`fnum` 0-199 and 400-599 reports 400 frames, 13.3 s, against a real 20.0 s. Set it to the span (last
78+
interval end) when intervals exist; the check that intervals cover the rows is kept on the row count.
79+
Consumers of `video.n_frames` are audited first (only `session_facts` is expected to read it); if
80+
another one assumes rows, this item is dropped from SP5 rather than widened.
81+
- **Horizontal-plane handedness** (`native3d.horizontal_axes`) returns the two non-vertical axes in file
82+
order, so `vertical_axis="y"` gives `(x, z)`, which is mirrored relative to the right-handed `(z, x)`.
83+
Audit result: magnitude metrics are unaffected, but **IL-11's `mean_heading_rad` and the sign of
84+
`left_right_turn_bias` are mirrored** for `vertical_axis` of `x` or `y`. Fix: return the two axes in
85+
cyclic order after the vertical one (`z -> (x, y)`, `x -> (y, z)`, `y -> (z, x)`). `vertical_axis="z"`,
86+
the default, is unchanged. Not fixed here: `flip` negates the vertical axis, which also mirrors the
87+
view from above; that stays documented (Known Issues in SP6) rather than silently permuting a
88+
horizontal axis.
89+
- **IL-15 token without a water column** is done in SP2.
90+
91+
## 6. Not doing: excluding the water column from the cache key
92+
93+
The review suggests dropping `calibration.water_column` from the preprocessing cache key because
94+
`apply_water_column` is a post-hoc transform. The cache stores the object returned by `preprocess()`,
95+
which already includes `apply_calibration_and_zones` (calibration, the water column and zones), so the
96+
water column is part of what is cached. Removing it from the key would return stale depths after the
97+
user changes the column. Splitting the cache before and after calibration is a larger change than the
98+
cost it saves (a re-preprocess when the column changes), so SP5 leaves it as it is.
99+
100+
## 7. Order of work and risk
101+
102+
1. `vertical_cm` helper and the water-column masking (tests first; changes native numbers).
103+
2. Inverted `FusionSettings` and the `align.py` sign.
104+
3. `vertical_axis` rule in `_native_rule`.
105+
4. `horizontal_axes` order (changes IL-11 / turn-bias signs for `vertical_axis` x or y).
106+
5. `n_frames` span, if the audit allows.
107+
6. Dialog and Calibration page text, README wording, CHANGELOG.
108+
109+
One PR per numbered group if the groups grow; the first two are independent of the rest.

0 commit comments

Comments
 (0)